Applications | Pharmaceutical industry & Pharmaceutical products Chemical industry Fossil raw materials Glass, Ceramics & Plastics Industry Vehicles & Road Traffic Show all Shipping Smart Factory Electrical industry Mechanical engineering & Plant construction Metal industry Energy Semiconductor industry |
Rise time (pressure) | 1 to 10 ms |
Accuracy (±) | 0.15 to 1.5 % |
Pressure measurement range | -1 to 400 bar |
Pharmaceutical industry & Pharmaceutical products
1 - 20 / 653
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products Vehicles & Road Traffic Energy |
Pressure measurement range | 0 to 600 mH2O |
Accuracy (±) | 0 to 0.5 % |
Measured media | Flammable gases Vapor Refrigerant Show all Food Paste-like media Gaseous media Fuels Oils Oxygen Non-aggressive media Air Non-combustible gases Dry gases Fuel oil Neutral gases Water Non-aggressive gases Semifluid media Nitrogen CO2 Liquids Hydraulic fluids Highly viscous liquids Non-corrosive dry gases Clean, dry air Non-corrosive liquids Non-corrosive gases Coolant Non-aggressive air Air, non-condensing non-aggressive, non-flammable gases Compressed air |
Applications | Pharmaceutical industry & Pharmaceutical products Chemical industry Railways & Rail Transport Vehicles & Road Traffic Heating/ Air conditioning/ Ventilation Show all Rail vehicle construction Energy Laboratory technology Construction |
Response time | 5 to 8,000 ms |
Pressure measurement range | 10 to 1,000 bar |
Accuracy (±) | 0 to 0.5 % |
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products Vehicles & Road Traffic Energy |
Pressure measurement range | 0 to 250 bar |
Accuracy (±) | 0 to 0.5 % |
Measured media | Aggressive media Flammable gases Vapor Show all Refrigerant Lacquers/paints Food Paste-like media Gaseous media Fuels Oils Oxygen Non-aggressive media Non-combustible gases Dry gases Fuel oil Neutral gases Water Non-aggressive gases Semifluid media CO2 Liquids Hydraulic fluids Highly viscous liquids Non-corrosive dry gases Clean, dry air Non-corrosive liquids Non-corrosive gases Coolant Non-aggressive air Air, non-condensing Contaminated media non-aggressive, non-flammable gases |
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products Chemical industry Fossil raw materials Paper industry & Pulp industry Show all Shipping Smart Factory Electrical industry Mechanical engineering & Plant construction Metal industry Energy Semiconductor industry |
Response time | 5 to 8,000 ms |
Pressure measurement range | 0 to 600 bar |
Accuracy (±) | 0 to 0.5 % |
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products Chemical industry Glass, Ceramics & Plastics Industry Paper industry & Pulp industry Show all Shipping Smart Factory Electrical industry Mechanical engineering & Plant construction Metal industry Waste management Energy Semiconductor industry |
Pressure measurement range | 0 to 100 bar |
Accuracy (±) | 0 to 0.5 % |
Measured media | Aggressive media Brake fluid Media containing solids Show all Refrigerant Corrosive media Paste-like media Acid Seawater Oils Non-aggressive media Water Salt water Wastewater Semifluid media Liquids Highly viscous liquids Rubber Non-corrosive liquids Coolant Contaminated media |
Applications | Pharmaceutical industry & Pharmaceutical products Fossil raw materials Heating/ Air conditioning/ Ventilation Energy |
Response time | 5 to 8,000 ms |
Pressure measurement range | 0 to 1,000 bar |
Accuracy (±) | 0 to 1 % |
Applications | Pharmaceutical industry & Pharmaceutical products Chemical industry Fossil raw materials Glass, Ceramics & Plastics Industry Paper industry & Pulp industry Show all Vehicles & Road Traffic Shipping Heating/ Air conditioning/ Ventilation Fisheries & Aquaculture Smart Factory Electrical industry Mechanical engineering & Plant construction Metal industry Energy Semiconductor industry |
Static pressure, max. | 1,000 bar |
Scanning rate | 500 to 1,000 Hz |
Reaction time | 2 ms |
Applications | Pharmaceutical industry & Pharmaceutical products |
Accuracy (±) | 0.25 to 0.5 % |
Pressure measurement range | -1 to 40 bar |
Diaphragm material | Stainless steel 1.4435 Hastelloy |
Applications | Pharmaceutical industry & Pharmaceutical products Chemical industry Laboratory technology |
Detection range water/ liquid media (l/min) | 0 to 3,000 ml/min |
Measured medium | Beer Liquids Hygienic applications Show all Conductive liquids Low-viscosity liquids Vegetable oil Pharmaceutical Lubricants Water Water-based media Coolant Liquid media Fruit juices Water with glycol Human blood Glycol solutions Cooling water Process water Water-based liquids Conductive, liquid media |
Measurement principle | Ultrasound technology |
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products |
Accuracy (±) | 0.25 to 0.5 % |
Pressure measurement range | -1 to 40 bar |
Measured media | Paste-like media Water Semifluid media |
Applications | Pharmaceutical industry & Pharmaceutical products Chemical industry Energy |
Accuracy (±) | 0.1 % |
Pressure measurement range | -1 to 600 bar |
Measured media | Brake fluid Vapor Gaseous media Show all Oils Non-aggressive media Neutral gases Liquids Coolant |
Applications | Pharmaceutical industry & Pharmaceutical products |
Medium temperature range | -40 to 300 °C |
Protection class/protection class of electr. connection | IP 69 IP67 |
Housing material (see data sheet for more information) | Stainless steel |
Applications | Pharmaceutical industry & Pharmaceutical products |
Protection class/protection class of electr. connection | IP 69 IP67 |
Housing material (see data sheet for more information) | Stainless steel |
Design/housing | Cylindrical |
Applications | Pharmaceutical industry & Pharmaceutical products |
Medium temperature range | -40 to 125 °C |
Protection class/protection class of electr. connection | IP 69 IP67 |
Housing material (see data sheet for more information) | Stainless steel |
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products Chemical industry Laboratory technology |
Supply voltage | 5 to 30 V DC |
Hose diameter (internal) | 3.2 to 19 mm |
Housing material | ABS plastic |
Applications | Hospital engineering Medical devices Pharmaceutical industry & Pharmaceutical products Chemical industry |
Maximum flow | 12,000 ml/min |
Flow rate | 0 to 12,000 ml/min |
Measured medium | Beer Liquids Conductive liquids Show all Non-conductive liquids Low-viscosity liquids Vegetable oil Drinking water Water Coolant Water with glycol Human blood Cooling water Water-based liquids |
Applications | Pharmaceutical industry & Pharmaceutical products Glass, Ceramics & Plastics Industry Vehicles & Road Traffic Mechanical engineering & Plant construction Environmental monitoring / Environmental observation Show all Packaging industry Intelligent mine monitoring |
Accuracy (±) | 1 mm |
Response time | 5 to 8,000 ms |
Repeatability (±) | 1 mm |
Applications | Medical devices Pharmaceutical industry & Pharmaceutical products |
Accuracy (%) | 0.125 to 0.25 % |
Measurement range from... to | -1 to 600 bar |
Measurement rate | 5 Hz |
Applications | Pharmaceutical industry & Pharmaceutical products Glass, Ceramics & Plastics Industry Vehicles & Road Traffic Mechanical engineering & Plant construction Metal industry Show all Environmental monitoring / Environmental observation Packaging industry Intelligent mine monitoring Bridge monitoring |
Accuracy (±) | 300 µm |
Repeatability (±) | 100 µm |
Measurement range | 0.1 to 40 m |
Sensors play a crucial role in the pharmaceutical industry and in the manufacture of pharmaceutical products. They are used to measure and monitor various parameters to ensure the quality and safety of products, such as the temperature sensor used in the storage and transportation of medicines. Precise temperature monitoring ensures that the medicines are stored under the right conditions to maintain their effectiveness. Another important sensor is the pressure sensor, which is used in the dosing of medication. It monitors the pressure during the filling process to ensure that the right amount of the active ingredient gets into each individual tablet or capsule, and sensors also play a crucial role in the production of pharmaceutical products. They are used to monitor various parameters such as pH value, viscosity and concentration. By continuously measuring these parameters, the quality of the products can be monitored during the manufacturing process and adjusted if necessary, and sensors are also used in quality assurance. They enable the monitoring of processes and the identification of deviations to ensure that products comply with quality standards. overall, sensors play a crucial role in the pharmaceutical industry and in the manufacture of pharmaceutical products. They help to ensure the quality and safety of the products and thus support people's health and well-being.