The DustTrak range of dust monitors is the best choice for real-time aerosol measurement. In contrast to conventional weight-based sampling, the real-time dust monitoring offered by the DustTrak provides instant display and evaluation of measurement data, so these devices are used by customers for qualitative and quantitative determination of particles, while finding anomalous or conspicuous values that require a response within a few hours or at most a few days. Amongst other things, these devices are used for the classification of cleanrooms according to DIN ISO 14644 and EU GMP and are accompanied by a calibration certificate in accordance with ISO 21501-4. They are divided into two main sub-areas, single particle count and particle count. the DustTrak range of dust monitors can detect PM1, PM2.5, permeable size, PM10 and total size simultaneously without the need for a size selective inlet regulator.
Product features
Can measure aerosol contaminants such as dust, smoke, fire gases and fog
Touch screen with colour graphic display
Measuring principle: laser photometer with light scattering measurement
Battery powered with data logger
Easy to program and easy to operate
Real-time mass concentration measurement
Available as a stationary model and as a handheld measuring device
Technical parameters
Particle size range: 0.1 to 10µm
Aerosol concentration measurement range: 8530 steady state model, 0.001 to 400 mg/m3
Dispersion: ±0.1% of the measured value or 0.001 mg/m3, larger values apply
Zero stability: ±0.002mg/m3 every 24 hours at 10 second time constant
Flow rate: 3.0L/min factory set, 1.40 to 3.0L/min, user adjustable
Flow rate accuracy: ±5% of factory set point, internal flow control
Temperature coefficient: +0.001 mg/m3 per °C
Operating temperature: 0 to 50°C
Storage temperature: -20 to 60°C
Operating humidity: 0-95% relative humidity, non-condensing
Time constant: user adjustable, 1 to 60 seconds
Data logger: 5MB integrated memory (>60,000 data points) for 45 days with 1 minute memory interval
Storage interval: user adjustable, 1 second to 1 hour
Applications
Industrial/occupational hygiene testing
Indoor air quality surveys and measurements
Environmental monitoring / particulate matter measurement
Indoor and outdoor congestion monitoring
Basic extrapolation and particle size separation tasks
Point source monitoring
Production monitoring
Remote monitoring
Emission monitoring
Aerosol studies