Deltronic (different versions)
Item number: - Price on request
Delivery time:Delivery time on request
Differential pressure sensor
Sensors for continuous monitoring of oil filters in hydraulic systems with simultaneous control of the oil temperature.
Attributes
Sensors for continuous monitoring of oil filters in hydraulic systems with simultaneous control of the oil temperature.
Attributes
- High differential overpressure resistance
- Small hysteresis with low leakage rate
- Status indication: two switching outputs in the following ranges
- 1.82 to 2.46 bar
- 2.40 to 3.38 bar
- 5.21 to 7.07 bar
- Alternatively one switching output and one analog output 4 to 20 mA
- IP68
- Deltronic HZ9790ZH24-DC (2.4 bar, with cold start suppression at 27°C)
- Deltronic HZ9790ZH34-DC (3.4 bar, with cold start suppression at 27°C)
- Deltronic HZ9790ZH69-DC (6.9 bar, with cold start suppression at 27°C)
- Deltronic HZ9792ZH24-DC (2.4 bar, with cold start suppression at 37°C)
- Deltronic HZ9792ZH34-DC (3.4 bar, with cold start suppression at 37°C)
- Deltronic HZ9792ZH69-DC (6.9 bar, with cold start suppression at 37°C)
- Deltronic HZ9790ZH24-DCYD (2.4 bar, without cold start suppression)
- Deltronic HZ9790ZH34-DCYD (3.4 bar, without cold start suppression)
- Deltronic HZ9790ZH69-DCYD (6.9 bar, without cold start suppression)
- Deltronic HZ9788ZH24-DB (2.4 bar, with cold start suppression at 27°C)
- Deltronic HZ9788ZH34-DB (3.4 bar, with cold start suppression at 27°C)
- Deltronic HZ9788ZH69-DB (6.9 bar, with cold start suppression at 27°C)
- Deltronic HZ9788ZH24-DBYD (2.4 bar, without cold start suppression)
- Deltronic HZ9788ZH34-DBYD (3.4 bar, without cold start suppression)
- Deltronic HZ9788ZH69-DBYD (6.9 bar, without cold start suppression)
- Deltronic HZ9788ZH24-DC (2.4 bar, with cold start suppression at 27°C)
- Deltronic HZ9788ZH34-DC (3.4 bar, with cold start suppression at 27°C)
- Deltronic HZ9788ZH69-DC (6.9 bar, with cold start suppression at 27°C)
- Deltronic HZ9788ZH24-DCYD (2.4 bar, without cold start suppression)
- Deltronic HZ9788ZH34-DCYD (3.4 bar, without cold start suppression)
- Deltronic HZ9788ZH69-DCYD (6.9 bar, without cold start suppression)
- Analog Deltronic HZ0856D800 (8.0 bar, with analog output 4-20mA)
- Analog Deltronic HZ0856D400 (4.0 bar, with analog output 4-20mA)
- Analog Deltronic HZ0856D250 (2.5 bar, with analog output 4-20mA)
Attributes of Deltronic (different versions)
May differ from supplier data
Signal inputs/outputs and interfaces
Signal output 4…20 mA
Housing / Design / Mechanical data / Materials
Housing material Stainless steel
Customized versions
Customized versions OEM version
Basic data
Display accuracy (±) 2.5 %
Operating overpressure, max. 20 MPa