Flow Transmitter RRI - RRI-025-G-V-V-120-N-05-K-A-K
Item number: RRI-025-G-V-V-120-N-05-K-A-K Price on request
Delivery time:Delivery time on request
The flow meter consists of an impeller which is set in rotation by the flowing medium. The speed of the rotor is proportional to the flow rate per time. The rotor is equipped with stainless steel clamps (optionally titanium or Hastelloy®). The reception of the flow proportional speed is done by an inductive proximity switch.
Attributes of Flow Transmitter RRI - RRI-025-G-V-V-120-N-05-K-A-K
May differ from supplier data
Product environmental influences (protection class/temperature)
Process pressure, max. 16 to 580 bar
Medium temperature range 0 to 60 °C
Protection class IP 67
Housing / Design / Mechanical data / Materials
Weight 500 g
Sealing material NBR
Housing material (see data sheet for more information) PVDF
Connection head material PVDF
Basic data
Accuracy (%) 3 %
Maximum flow 72 l/min
Flow rate 3 to 60 l/min
Measurement process Impeller
Measured medium Water
Process connection
Inlet bore 12 mm
Nominal diameter DN up to DN 25
Process connection/installation Internal thread
Electrical data / Signal connections
Power consumption 502,000 mA
Electrical connection 2 m cable
Rotor With 5 brackets
Clamp material 1.4310
Signal connection
Cable sheath material PVC
Approvals / Certificates / Performance level / Integrity level
Approvals/certificates/test marks CE
More functions and options
More functions/options Short-circuit proof
Signal inputs/outputs and interfaces
Signal output NAMUR