Laser triangular displacement sensor TS-P25
Item number: TS-P25 Applications Glass, Ceramics & Plastics IndustryPrecision mechanics & OpticsAircraft & Spacecraft constructionPC, Tablet, Mobile & WearableEnergySemiconductor industry
Price on request
Delivery time:Delivery time on request
Ultra-fast Sampling Speed of 160kHz
The sampling speed is an order of magnitude higher than traditional models on the market, with a dedicated processor performing high-speed digital processing of the light spot signal, capable of meeting the demands for both high-speed and high-precision measurements reliable measurements can be taken of objects moving at high speeds, rotating rapidly, or vibrating quickly.
High Linear Accuracy of ±0.02% of F.S.
The independently designed high spatial resolution emission and reception mirror groups bring excellent linear characteristics. With an automated calibration system of nanometer-level precision based on traceability to a laser interferometer, it meets the high-precision, mass-production performance calibration requirements of sensor products.
High Repeatability of 0.02μm
High Repeatability of0.02μmHigh-sensitivity,high signal-to-noise ratio components are used, with internal signal digitization implemented in the probe head, significantly reducing noise interference. Moreover, the design is optimized for application sites, minimizing the impact of environmental temperature fluctuations and structural vibrations on measurement accuracy, truly delivering high-precision measurement capabilities to the client.
The sampling speed is an order of magnitude higher than traditional models on the market, with a dedicated processor performing high-speed digital processing of the light spot signal, capable of meeting the demands for both high-speed and high-precision measurements reliable measurements can be taken of objects moving at high speeds, rotating rapidly, or vibrating quickly.
High Linear Accuracy of ±0.02% of F.S.
The independently designed high spatial resolution emission and reception mirror groups bring excellent linear characteristics. With an automated calibration system of nanometer-level precision based on traceability to a laser interferometer, it meets the high-precision, mass-production performance calibration requirements of sensor products.
High Repeatability of 0.02μm
High Repeatability of0.02μmHigh-sensitivity,high signal-to-noise ratio components are used, with internal signal digitization implemented in the probe head, significantly reducing noise interference. Moreover, the design is optimized for application sites, minimizing the impact of environmental temperature fluctuations and structural vibrations on measurement accuracy, truly delivering high-precision measurement capabilities to the client.
Attributes of Laser triangular displacement sensor TS-P25
May differ from supplier data
Basic data
Measurement frequency 160 kHz
Repeatability (±) 0.02 µm
Accuracy 0.02 ‰
Measurement range 24 to 26 mm
Measurement process Laser
Housing / Design / Mechanical data / Materials
Sensor weight, approx. 372 g
Product environmental influences (protection class/temperature)
Operating temperature range 0 to 50 °C
Protection class IP 67
Signal inputs/outputs and interfaces
Interfaces Ethernet
Approvals / Certificates / Performance level / Integrity level
Approvals/certificates/test marks CE ROHS