Level measurement device
Item number: OPTIWAVE 5400 C Applications Chemical industryFossil raw materialsEnergy
Price on request
Delivery time:Delivery time on request
Attributes of Level measurement device
May differ from supplier data
Basic data
Accuracy (mm) 2 mm
Medium temperature range/process temperature -50 to 200 °C
Measurement range 0 to 100 m
Additional measurement possibilities Filling level
Measured medium Liquids
Measurement principle FMCW radar
Probe type Horn antenna
Product environmental influences (protection class/temperature)
Operating temperature range 0 °C
Protection class IP 68 IP66
Signal inputs/outputs and interfaces
Interfaces Profibus PA
Signal output 4…20 mA HART protocol
Approvals / Certificates / Performance level / Integrity level
Certificates/approvals ATEX IECEx NEPSI Show all WHG cQPUS (IS/NI) CRN ASME B31.3 VLAREM II NACE cQPSus (XP) EAC API 2350 DNV-GL
Safety integrity level SIL 2 SIL 3
Process connection
Process connection/installation G 1 1/2" 11/2" NPT
Typical applications
Typ. applications Pharmaceutical industry Chemicals industry Oil and gas