Off-line Filter
Item number: FNA 08-763 Price on request
Delivery time:Delivery time on request
Protection against wear: By means of filter elements that in full-flow filtration, meet even the highest demands regarding cleanliness classes. Protection against malfunction: Through installation near to the control valves or other expensive components. The specific determined flow rate guarantees a closed by-pass valve even at ν ≤ 200 mm²/s (cold start condition).
Attributes of Off-line Filter
May differ from supplier data
Basic data
Rated flow 10 l/min
Max. operating pressure 4 bar
Hydraulic fluid temperature, max. 65 °C
Suction height max. 1.5 m
Recommended tank size ≤ 400 to 1,500 l
Contamination display Electrical contamination indicator Can be retrofitted optical, mechanical clogging indicators
Hydraulic fluid Mineral oil Hydraulic oil HEES Hydraulic oil HETG
Filter design Bypass flow filter for in-line installation
More functions and options
More functions/options Pressure measuring port
Electrical data / Signal connections
Motor operating voltage 110 VAC
Process connection
Pressure connection Inlet 11/16-12 UN-2B
Pressure connection outlet 3/4-16 UN-2B