Off-line Filter
Item number: FNS 060-163 Price on request
Delivery time:Delivery time on request
Protection against wear: By means of filter elements that in full-flow filtration, meet even the highest demands regarding cleanliness classes. Protection against malfunction: Through installation near to the control valves or other expensive components. The specific determined flow rate guarantees a closed by-pass valve even at ν ≤ 200 mm²/s (cold start condition).
Attributes of Off-line Filter
May differ from supplier data
Basic data
Rated flow 4 l/min
Max. operating pressure 5 to 320 bar
Hydraulic fluid temperature, max. 100 °C
Contamination display Electrical contamination indicator Can be retrofitted optical, mechanical clogging indicators
Hydraulic fluid Mineral oil Hydraulic oil HEES Hydraulic oil HETG
Filter design Bypass flow filter for in-line installation
Process connection
Pressure connection Inlet G1"
Pressure connection outlet G1"
More functions and options
More functions/options Flow control valve