Off-line Filter
Item number: FNU 08-653 Price on request
Delivery time:Delivery time on request
Protection against wear: By means of filter elements that in full-flow filtration, meet even the highest demands regarding cleanliness classes. Protection against malfunction: Through installation near to the control valves or other expensive components. The specific determined flow rate guarantees a closed by-pass valve even at ν ≤ 200 mm²/s (cold start condition).
Attributes of Off-line Filter
May differ from supplier data
Basic data
Rated flow 8 l/min
Max. operating pressure 4 bar
Hydraulic fluid temperature, max. 65 °C
Bypass valve set pressure 4 bar
Suction height max. 6 m
Recommended tank size ≤ 800 l
Hydraulic fluid Mineral oil Hydraulic oil HEES Hydraulic oil HETG Show all Other hydraulic fluids on request
Filter design Bypass filter units (offline filter)
Contamination display optical, mechanical clogging indicators
Process connection
Pressure connection Inlet G1"
Pressure connection outlet G1"
Electrical data / Signal connections
Motor operating voltage 400/690 VAC (3x)