Pressure sensor
Item number: eds-4000 Price on request
Delivery time:Delivery time on request
Attributes of Pressure sensor
May differ from supplier data
Signal inputs/outputs and interfaces
Switching frequency max. 500 Hz
Switching voltage, max. 1,000 V
Switching current per switching output, max. 8 A
Switching function NC contact NO contact
Basic data
Static pressure, max. 600 psi
Resonance frequency 0 Hz
Bursting pressure 400 bar
Non-linearity (±) 1 %
Temperature coefficient of sensitivity 0.9 %/°C
Permissible overpressure / overload pressure max. (%) 2 %
Rise time (pressure) 5 s
Sensitivity (Acceleration) 200 mV/g
Isolation voltage 500 V
Overload limit (shock) (±) 2.2 g
Pressure measurement range 6 to 16 bar
Accuracy (hPa) 0.1 hPa
Measurement possibilities (static/dynamic) Static
Measuring task/measurement object Switch
Diaphragm material Brass
Measured media Pressure
Additional measurement possibilities EC
Approvals / Certificates / Performance level / Integrity level
Salt spray test 11 h
Approvals/certificates/test marks ATEX UL
Protection class ATEX
Safety integrity level SIL 1
Housing / Design / Mechanical data / Materials
Tightening torque 5 Nm
Installation type -
Electrical data / Signal connections
Cable length 30 m
Power consumption 502,000 mA
Supply voltage 14 to 28 V DC
Number of pins 5-pin
Cable sheath material PVC
Product environmental influences (protection class/temperature)
Operating temperature range 0 °C
Medium temperature range -40 to 100 °C
Protection class/protection class of electr. connection IP67
Customized versions
Customized versions Cable length
Process connection
Cable connection/ design M12x1 Cable
Process connection/pressure connection M12x1