Pressure sensor
Item number: hda-4000-aa-exia Price on request
Delivery time:Delivery time on request
Attributes of Pressure sensor
May differ from supplier data
Basic data
Non-linearity (±) 0.1 %
Static pressure, max. 100 bar
Resistance tolerance Min. 280 to 100,000,000 Ω
Permissible overpressure / overload pressure max. (%) 120 %
Isolation voltage 500 V
Sensitivity (Acceleration) 5 mV/g
Linearity 0.1 %
Material thickness max. 1 mm
Overload limit (shock) (±) 20 g
Resistance range 280 Ω
Accuracy (hPa) 0.5 hPa
Compensated temperature range 85 °C
Measurement possibilities (static/dynamic) Static
Measuring task/measurement object Pressure measurement Pressure
Thread-thread length NPT
Signal inputs/outputs and interfaces
Switching frequency max. 4 Hz
Switching current per switching output, max. 20 mA
Signal output 4~20mA
Additional signal outputs mA
Housing / Design / Mechanical data / Materials
Tightening torque 20 Nm
Installation type -
Housing material (see data sheet for more information) Metal
Electrical data / Signal connections
Cable length 30 m
Supply voltage 2 to 4 V
Number of pins 2-pin
Electrical connection M12
Product environmental influences (protection class/temperature)
Operating temperature range 85 °C
Operating Humidity 10 to 90 %
Medium temperature range 6 °C
Customized versions
Customized versions Cable length
Approvals / Certificates / Performance level / Integrity level
Approvals/certificates/test marks ATEX UL IECEx
Safety integrity level SIL2
Performance level PLd
Protection class "C T85/95° C Db"
More functions and options
More functions/options Overvoltage protection
Process connection
Cable connection/ design Cable
Process connection/pressure connection 1/2 NPT