Universal Vibration Monitor
Item number: M14 Applications Mechanical engineering & Plant constructionMetal industrySemiconductor industry
Price on request
Delivery time:Delivery time on request
• Monitoring of unbalance vibration to ISO 10816 / ISO 20816
\r\n• Monitoring of bearing vibration
\r\n• Detection of particular vibration frequencies by FFT
\r\n• RMS and peak values
\r\n• Inputs for IEPE transducers
\r\n• USB and RS-485 interfaces for digital setup and measurement
\r\n• Level indication at front side
\r\n• Relay outputs with adjustable thresholds and delays
\r\n• Isolated 4 .. 20 mA current loop
\r\n• Self-test functions
\r\n• Teach-in for alarms (M14)
\r\nMade in Germany
\r\nShort delivery time
\r\n• Monitoring of bearing vibration
\r\n• Detection of particular vibration frequencies by FFT
\r\n• RMS and peak values
\r\n• Inputs for IEPE transducers
\r\n• USB and RS-485 interfaces for digital setup and measurement
\r\n• Level indication at front side
\r\n• Relay outputs with adjustable thresholds and delays
\r\n• Isolated 4 .. 20 mA current loop
\r\n• Self-test functions
\r\n• Teach-in for alarms (M14)
\r\nMade in Germany
\r\nShort delivery time
Attributes of Universal Vibration Monitor
May differ from supplier data
Basic data
Acceleration measurement range 1 to 7,000 m/s²
Measurement accuracy 5 %
Channel count 1 Kanal
Frequency range 0.3 to 11.5 Hz
Vibration velocity 1 to 700 mm/s
Measurement possibilities Vibration velocity Acceleration measurement
Connectable sensor types (uni/triaxial) Uniaxial IEPE/ICP® sensors
Measurement evaluations RMS value Peak value Frequency analysis
Signal inputs/outputs and interfaces
Interfaces RS-485 USB
Signal output 0–10 VDC 4-20 mA
Typical applications
Typical applications Machine condition monitoring Bearing vibration measurements Running smoothness measurement Show all Roller bearing monitoring
Software interfaces / Driver software
Software support Proprietary software Parameterization software
More functions and options
More functions/options Overload indicator Measurement device settings can be saved FFT Show all Switching output for alarm
Housing / Design / Mechanical data / Materials
Design/assembly DIN top hat rail housing