This device measures the relative humidity and temperature of air or non-corrosive/non-ionising gases. From this value other values can be derived and displayed than the relative humidity.
Product parameters
Display range humidity
Relative air humidity: 0.0 - 100.0% relative humidity
Wet bulb temperature: -27.0 - 60.0°C (or -16.6 - 140.0°F)
Dew point temperature: -40.0-60.0°C (or -40.0-140.0°F)
Enthalpy: -25.0,999.9kJ/kg
Mixing ratio (atmospheric humidity): 0.0-640.0 g/kg
Absolute humidity: 0.0-200.0 g/m3
Recommended humidity measurement range
Standard: 20.0 - 80.0% relative humidity
Humidity sensor operating range: option "high humidity": 5.0 - 95.0% RH
Range temperature: -40.0 to 120.0°C or -40.0 to 248.0°F
Accuracy display
Output signal: (at a nominal temperature of 25°C) Relative air humidity: ±2.5% RH (within the recommended measurement range)
Temperature: ±0.4%, ±0.2°C, ±0.2% FS of measured value
Medium: non-corrosive gas
Sensor: capacitive polymer humidity sensor and Pt1000
Temperature compensation: automatic
Frequency: per second
Adjustment: digital offset and scale adjustment for humidity and temperature
Min/max memory: storage of min and max measured values
Housing: ABS (IP65, except sensor head)
Dimensions: 82x80x55mm (without elbow-type plug and sensor tube)
For option "Kabel": Sensor head diameter 14mm*68mm, 1m Teflon cable, high humidity sensor
Mounting: Hole for wall mounting (in the housing - accessible after removal of the cover)
Mounting distance: max. 50x70 mm. Shaft diameter of mounting screws 4mm
Electrical connection: Elbow type plug in accordance with DIN 43650 (IP65)
Maximum value wire cross section: 1.5mm², wire/cable diameter 4.5 to 7mm
Battery compatibility: The device complies with the basic level of protection specified in the regulations of the approximation committee of the Member States' legislation on electromagnetic compatibility (2004/108/EG).
Additional error according to EN 61326-1:2006: <1% FS. When connected, the long leads must be protected against voltage surges by adequate measures.
Scaling: display value via input 4mA (0V respectively) and 20mA (1V/10V respectively) output, both freely scalable
Connection: 4-20 mA (2-wire) voltage (3/4-wire)
Auxiliary energy: 4-20 mA: Uv=12-30V DC
0-1V: Uv=12-30 volts DC max. 10mA
0-10V: Uv=18-30V DC max. 10mA
Impedance: 4-20 mA: RA (ohms) < (UV-12V)/0,02A)
Example: For Uv=18V, RA<(18V-12V)/0.02A => RA<300 ohms
Allowable load: 0-1 (10) V: RL (Ohm) > 3000Ohm