The GSEM 517 Ex transmitter is used for the detection of ammonia in Ex zones. The measuring principle of the measuring element used is based on catalytic combustion (also called heat tone or pelistor). The heat tone/pelistor measuring principle reacts to additional gases, therefore cross-sensitivities to additionally occurring combustible gases should be considered
Attributes of Gas sensor
May differ from supplier data
Basic data
Measurement accuracy (MR end value) +/- 2 %
Measuring gas Ammonia
Gas entry via Diffusion
Measurement process Electrochemical
Approvals / Certificates / Performance level / Integrity level
Approvals/certificates ATEX
Protection class II 2G Ex d ia IIC T4 Gb
Signal inputs/outputs and interfaces
Signal output 4…20 mA
Switching output Relay
Interfaces KIMESSA CAN-BUS
More functions and options
More functions/options Display, integrated
Housing / Design / Mechanical data / Materials
Design Inline